Skip to main content
Schneider Electric A9F04103

Schneider Electric A9F04103 Acti9 iC60N MCB, 1P, C-Curve, 3

MPN A9F04103
Active

Schneider Electric Acti9 iC60N, miniature circuit breaker, 1P, C-curve, 3 A, 50 kA Icu at 240 V AC, DIN rail mount, white.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F04103 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity50 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 10 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C

All specifications

A9F04103 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width18 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

What the ratings mean for fit

The A9F04103 is a 1-pole Acti9 iC60N miniature circuit breaker with a C-curve, rated 3 A. Magnetic tripping occurs at 8 x In +/- 20 %. Breaking capacity is the headline here: 50 kA Icu at 240 V AC per EN/IEC 60947-2, and 6 kA Icn at 230 V AC per EN/IEC 60898-1. The Icu figure (ultimate breaking capacity) tells you it can safely interrupt a 50 kA fault once — enough for high-fault industrial panels. The Icn (rated short-circuit capacity) at 6 kA is the domestic/commercial standard. If your panel's prospective short-circuit current exceeds 6 kA at the breaker, you rely on the 60947-2 rating; if it's under 6 kA, either standard applies. For DC circuits, it breaks 15 kA at 12…60 V DC and 10 kA at 60…72 V DC. Rated insulation voltage is 500 V AC, and overvoltage category IV means it's rated for the mains supply point (not just downstream equipment). Pollution degree 3 (conductive pollution or dry non-conductive that becomes conductive) is typical for industrial control panels — no extra derating needed for dusty or humid environments.

Integration and mounting

Mounts on a DIN rail — 2 modules wide (18 mm per pitch). The double terminal accepts up to 25 mm² rigid or 16 mm² flexible wire, top or bottom. IP20 rated — suitable for enclosed distribution boards, not for washdown or outdoor exposure. Tropicalisation class 2 per IEC 60068-1 means it's treated against humidity and fungal growth for warm, damp environments.

MPN
A9F04103