Skip to main content
Schneider Electric A9F04140

A9F04140 Acti9 iC60 MCB, 1P C-curve 40 A, 10 kA, DIN rail

MPN A9F04140
Active

Schneider Electric Acti9 iC60N, A9F04140, 1-pole miniature circuit breaker, 40 A rated current, C-curve, 10 kA breaking capacity at 230 V AC, thermal-magnetic trip, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F04140 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 10 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C

All specifications

A9F04140 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width18 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F04140 is a 1-pole Acti9 iC60N miniature circuit breaker rated at 40 A with a C-curve trip characteristic.

Under the industrial standard (60947-2), the ultimate breaking capacity (Icu) is 10 kA at 220–240 V AC, 36 kA at 12–60 V AC, and 20 kA at 100–133 V AC. For DC circuits, it delivers 15 kA at 12–60 V DC and 10 kA at 60–72 V DC. Under the residential/light-commercial standard (60898-1), the rated short-circuit capacity (Icn) is 6 kA at 230 V AC. This dual rating means the breaker is suitable for both industrial distribution panels requiring high fault interruption and general-purpose final subcircuits. The C-curve (magnetic trip at 8 x In ±20%) is the standard choice for inductive loads like small motors, lighting ballasts, and transformers where inrush current is moderate. For a 40 A rating, the magnetic trip threshold is approximately 320 A, which avoids nuisance tripping on startup while clearing hard faults.

Panel integration

The 18 mm width (2 x 9 mm pitches) and 78.5 mm depth fit standard DIN-rail enclosures with minimal overhang. The IP20 finger-safe terminals accept rigid conductors up to 35 mm² or flexible up to 25 mm², with a stripping length of 14 mm and a tightening torque of 3.5 N.m. The toggle control and trip indicator provide local status at a glance. Pollution degree 3 rating means it tolerates conductive pollution in industrial environments, and tropicalisation class 2 (per IEC 60068-1) covers humidity up to 95% at 55°C.

Rated insulation voltage (Ui) is 500 V AC, and overvoltage category IV means it can be installed at the service entrance or main distribution board.