Specifications

A9F04663 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C

All specifications

A9F04663 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width36 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F04663 is an Acti9 iC60N miniature circuit breaker — 1P+N, 63 A rated current, C-curve trip characteristic. It carries a 36 kA Icu breaking capacity at 12-60 V AC (per EN/IEC 60947-2) and a 6000 A Icn at 230 V AC (per EN/IEC 60898-1). That dual-standard rating means it qualifies for both industrial panel (60947-2) and final-distribution (60898-1) duty, so you can spec it into a machine control cabinet or a sub-distribution board without swapping part numbers.

The 63 A rating on a 1P+N frame is the headline — it protects a single-phase line-neutral circuit at full 63 A continuous. The C curve (magnetic trip at 8 x In ±20 %) means it tolerates moderate inrush, typical of small motor loads, lighting banks, or transformer primaries, without nuisance tripping. The thermal-magnetic trip unit handles overloads (thermal bimetal) and short-circuits (solenoid) in one package, so no separate relay needed. Breaking capacity varies with voltage: 36 kA Icu at 12-60 V AC, 20 kA at 100-133 V AC, 10 kA at 220-240 V AC. At 230 V AC the Icn (IEC 60898-1 rating) is 6000 A.

Double terminals top and bottom accept 1-35 mm² rigid or 1-25 mm² flexible — enough for the 63 A feed. Wire strip length 14 mm.

MPN