Skip to main content
Schneider Electric A9F04704

A9F04704 Acti9 iC60N MCB, 4 A C-curve 3P+N, 50 kA Icu

MPN A9F04704
Active

Schneider Electric Acti9 iC60N miniature circuit-breaker, A9F04704, 4 A rated, C-curve, 3P+N, 50 kA Icu at 415 V AC, 6 kA Icn, thermal-magnetic trip, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F04704 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity50 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 25 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C

All specifications

A9F04704 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width72 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F04704 is an Acti9 iC60N miniature circuit-breaker rated 4 A with a C-curve, 3P+N poles, and a thermal-magnetic trip unit. The 50 kA Icu at 415 V AC (EN/IEC 60947-2) and 6 kA Icn (EN/IEC 60898-1) breaking capacities mean it handles high fault currents in commercial and industrial panels — the Icu rating governs the maximum short-circuit it can interrupt without damage, while the Icn rating covers the standard domestic/commercial duty cycle.

The 72 mm width (8 x 9 mm pitches) and 78.5 mm depth fit standard distribution boards. Double terminals accept 1–25 mm² rigid or 1–16 mm² flexible cable; strip length 14 mm, tightening torque 2 N.m. IP20 finger-safe terminals. Neutral is on the left. The toggle control and trip indicator provide local status. Separate earth-leakage protection block can be added alongside.

Rated for isolation (EN/IEC 60898-1 and 60947-2). Overvoltage category IV, pollution degree 3. Electrical durability 10,000 cycles, mechanical 20,000 cycles. Tropicalisation class 2 (IEC 60068-1). Limitation class 3. Operating frequency 50/60 Hz. Ambient humidity 95% at 55 °C.

MPN