Schneider Electric A9F05101

A9F05101 Acti9 iC60N 1A D Curve MCB, 50 kA Icu

MPN A9F05101
Active

Schneider Electric Acti9 iC60N, A9F05101, miniature circuit breaker, 1 A, D curve, 1 pole, 50 kA Icu at 240 V AC, thermal-magnetic trip, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F05101 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity50 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 10 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F05101 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width18 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The 1 A rating means it protects a circuit drawing up to 1 A continuous — sized for a control transformer primary, a PLC power supply feed, or a signal loop, not a motor branch. The D curve (magnetic trip at 12× In, ±20%) means it tolerates inrush up to roughly 14.4 A before instant tripping, so it suits loads with a high starting surge like small transformers or solenoid banks.

The single-pole (1P) form factor breaks only the line conductor; the neutral is switched separately or left solid. Double terminals top and bottom accept 1 to 25 mm² rigid or 1 to 16 mm² flexible, with a 14 mm strip length and 2 Nm tightening torque. The toggle actuator and trip indicator give local status without opening the panel door. IP20 finger-safe terminals suit enclosed panel use — not for wet or washdown locations.

Dual-certified to EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (household / similar) — so it qualifies for both panel-level distribution and final subcircuit protection. Pollution degree 3 (conductive pollution, typical in control cabinets without climate control). Overvoltage category IV (mains-level surge withstand). Suitability for isolation marked on the device, per both standards.

MPN
A9F05101