Skip to main content
Schneider Electric A9F05140

Schneider Electric A9F05140 Acti9 iC60N MCB, D Curve, 40 A,

MPN A9F05140
Obsolete

Schneider Electric Acti9 iC60N, A9F05140, miniature circuit breaker, 1P, 40 A, D curve, 36 kA breaking capacity at 12-60 V AC, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F05140 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity36 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 10 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F05140 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width18 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The A9F05140 is a 40 A, 1-pole miniature circuit breaker from the Schneider Acti9 iC60N family, built for distribution panels where you need a D-curve trip characteristic. On a 230 V AC lighting or general-purpose circuit a C curve would nuisance-trip; the D curve gives you the headroom without oversizing the breaker. Breaking capacity is where this part earns its keep in an industrial panel. At 12-60 V AC it's rated 36 kA Icu per EN/IEC 60947-2; at 220-240 V AC it's still 10 kA Icu. It also carries a 6000 A Icn rating at 230 V AC under the domestic-standard EN/IEC 60898-1, so it's dual-certified for both industrial and residential applications — useful if your BOM crosses both worlds. The thermal-magnetic trip unit is non-interchangeable, which is the norm for MCBs in this class — you spec the rating at order time and it stays. Isolation capability is confirmed to both standards, meaning you can safely use the toggle as a visible disconnect for downstream work.

Mounting and wiring — what to tell the panel builder

That's a generous wire range for a 40 A breaker — you can land a 6 mm² feed and still have room for a 16 mm² downstream tap in the same terminal. The toggle gives you a clear visual trip indicator — when the breaker trips, the handle settles in a mid-position that's easy to spot during a walk-down.

MPN
A9F05140