Schneider Electric A9F06132

Schneider Electric A9F06132 Acti9 iC60H MCB, B Curve 32 A 1P

MPN A9F06132
Active

Schneider Electric Acti9 iC60H miniature circuit breaker, A9F06132, 1P, B curve, 32 A rated current, 42 kA Icu breaking capacity at 12-60 VAC, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F06132 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F06132 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width18 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F06132 is an Acti9 iC60H miniature circuit breaker — 1-pole, B-curve, rated 32 A. The B curve (magnetic trip at 4 x In +/-20%) means it handles resistive and light inductive loads well but will nuisance-trip on high inrush currents from motors or transformers; spec it for lighting, heating, or general socket circuits, not motor feeders. At 230 VAC the Icn is 10,000 A per EN/IEC 60898-1, the standard for domestic and commercial distribution boards. The 18 mm width (2 x 9 mm pitches) snaps onto a DIN rail, and the double terminal accepts up to 35 mm² rigid or 25 mm² flexible — sized for a 32 A feed without pigtailing.

Deployment context

The toggle and trip indicator are visible through the enclosure door, so fault isolation doesn't require opening the panel. Pollution degree 3 (conductive pollution, occasional condensation) matches typical industrial environments per IEC 60947-2.

Dual-certified to EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (domestic/commercial). Suitability for isolation confirmed under both standards — the contact position indicator shows whether the contacts are open. Overvoltage category IV (for utility-side connection) and tropicalisation class 2 (55°C, 95% RH) per IEC 60068-1. Thermal-magnetic trip unit, no integral earth-leakage protection.

MPN