Skip to main content
Schneider Electric A9F06363

Schneider Electric A9F06363 Acti9 iC60H MCB, 63 A, 3P, B-Cur

MPN A9F06363
Active

Schneider Electric Acti9 iC60H, A9F06363, 3-pole miniature circuit breaker, 63 A rated current, B-curve, 15 kA breaking capacity at 400 V AC, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F06363 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C

All specifications

A9F06363 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width54 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F06363 is a 3-pole Acti9 iC60H miniature circuit breaker rated at 63 A with a B-curve trip characteristic. The 15 kA Icu at 380–415 V AC (and 10 kA Icn at 400 V under the domestic standard) gives it solid fault-clearing headroom for most panel applications without cascading upstream.

The 42 kA Icu at 12–133 V AC is the high side for low-voltage secondary taps; the more relevant number for a 400 V panel is the 15 kA Icu at 380–415 V AC (EN/IEC 60947-2) and 10 kA Icn at 400 V (EN/IEC 60898-1). That spread means it coordinates well downstream of a larger moulded-case breaker — you get full selectivity up to its interrupting rating without the nuisance of a main breaker tripping on a branch fault.

Panel integration

Snaps onto standard DIN rail; 54 mm wide (6 x 9 mm pitches) and 78.5 mm deep — fits a standard distribution board without overhang. IP20 rated, so it's for enclosure interiors only — no washdown exposure.

Trip curve and coordination

B-curve means magnetic trip between 3.2 x In and 4.8 x In (4 x In +/- 20 %). The thermal-magnetic trip unit handles overloads on the thermal side and short-circuits on the magnetic side, with a mechanical endurance of 20,000 cycles and electrical endurance of 10,000 cycles.

MPN