Skip to main content
Schneider Electric A9F06650

Schneider Electric A9F06650 Acti9 iC60H MCB, 50 A, 1P+N, Cur

MPN A9F06650
Active

Schneider Electric Acti9 iC60H, miniature circuit-breaker, 50 A, 1P+N, curve B, 42 kA breaking capacity at 12-60 V AC, thermal-magnetic trip, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F06650 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F06650 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width36 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

Acti9 iC60H at a glance

It is a 1P+N unit — one protected pole plus a switched neutral — and carries a 42 kA breaking capacity (Icu) at 12-60 V AC, which drops to 15 kA at 220-240 V AC per EN/IEC 60947-2. The thermal-magnetic trip unit gives you two layers of protection: a thermal bimetal for sustained overloads (heating up over time) and a magnetic coil for instantaneous short-circuit trips. The B-curve magnetic trip threshold is 4 x In ±20 %, so for a 50 A breaker the magnetic pickup sits between roughly 160 A and 240 A — fast enough to clear a hard short but tolerant of mild inrush from resistive loads. This makes it a distribution-grade MCB (Category A per EN/IEC 60947-2), not a motor-protection device. It is dual-rated to both EN/IEC 60898-1 (household-style MCB standard) and EN/IEC 60947-2 (industrial circuit-breaker standard), so it can be specified in residential consumer units or industrial panelboards. The 10,000 A Icn at 230 V AC under the 60898-1 standard is the domestic rating; the higher 60947-2 Icu figures apply when it is installed in an industrial enclosure with proper coordination. You get isolation capability certified under both standards, which means it can be used as a disconnecting means for downstream circuits.

Snaps onto a standard 35 mm DIN rail — 4 module pitches wide (36 mm per pole, so 4 x 9 mm = 36 mm total width). Height is 91 mm, depth 78.5 mm. Terminals accept double conductors: 1-35 mm² rigid or 1-25 mm² flexible, with a stripping length of 14 mm and a tightening torque of 3.5 N.m. The toggle control has a trip indicator window that shows green/red for contact position, so you can visually confirm the state without removing the cover.

MPN
A9F06650