Skip to main content
Schneider Electric A9F07370

Schneider Electric A9F07370 Acti9 iC60H MCB, C-Curve 0.5 A 3

MPN A9F07370
Active

Schneider Electric Acti9 iC60H, A9F07370, miniature circuit breaker, 0.5 A, C-curve, 3-pole, 70 kA Icu at 415 V AC, DIN rail.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F07370 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity70 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F07370 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width54 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The A9F07370: The 0.5 A In is the continuous current the breaker carries without tripping — sized for a low-current load like a signal transformer or a small power supply, not a motor or heater bank. The C-curve (magnetic trip at 8 x In +/- 20 %, so 4 A nominal) means it holds through moderate inrush, typical of small transformers and capacitive loads, but trips fast on a hard short. The 70 kA Icu at 415 V is the maximum fault current it can interrupt once without damage — that's a high-fault rating for a 0.5 A MCB, so it can sit on a panel fed by a large transformer without needing a current-limiting fuse upstream. The thermal-magnetic trip unit covers both overload (thermal bimetal) and short-circuit (solenoid).

Snaps onto a DIN rail (mounting support: DIN rail). The 3-pole body takes 6 x 9 mm pitches on the rail — 54 mm wide, 91 mm tall, 78.5 mm deep. Terminals accept double conductors up to 25 mm² rigid or 16 mm² flexible; wire strip length is 14 mm. IP20 rated, so it's for inside the enclosure only. The toggle control and trip indicator give local status without opening the door.

MPN
A9F07370