Schneider A9F07670 Acti9 iC60H MCB, 0.5 A C-curve, 70 kA

MPN A9F07670
Obsolete

Schneider Electric Acti9 iC60H, miniature circuit breaker, 0.5 A, C-curve, 1P+N, 70 kA breaking capacity, DIN rail, white.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F07670 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity70 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 70 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F07670 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width36 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider A9F07670 is an Acti9 iC60H miniature circuit breaker — a 1P+N unit rated at 0.5 A with a C-curve, designed for distribution boards on DIN rail. The 10 kA Icn per EN/IEC 60898-1 covers the domestic/commercial rating side. Dual-standard certification means it satisfies both the industrial (60947-2) and installation (60898-1) standards, so it works in mixed environments without a coordination headache.

At 0.5 A rated current (In), this is a low-current MCB — it protects a control transformer primary, a small power supply, or a signal-loop feeder, not a motor or a general-purpose socket circuit. The C-curve (magnetic trip at 8 x In ±20 %, so 4 A nominal) means it tolerates moderate inrush without nuisance tripping, which suits transformer or capacitive loads. The thermal-magnetic trip unit gives both overload (thermal bimetal) and short-circuit (solenoid) protection in one package. The 10 kA Icn per EN/IEC 60898-1 is the standard domestic rating; the 70 kA figure is what the industrial spec calls for.