Skip to main content
Schneider Electric A9F08125

Schneider Electric A9F08125 Acti9 iC60H MCB, 25 A, 1P, D Cur

MPN A9F08125
Obsolete

Schneider Electric Acti9 iC60H, miniature circuit breaker, 25 A, 1P, D curve, 15 kA Icn at 230 V AC, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F08125 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity42 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 15 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 10000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F08125 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width18 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

Acti9 iC60H miniature circuit breaker, 25 A, D curve

The Schneider Electric A9F08125 is a 1-pole Acti9 iC60H miniature circuit breaker rated at 25 A with a D tripping curve, designed for distribution applications where high inrush currents — typical of motor, transformer, or lighting loads — require a magnetic trip threshold of 12 x In (±20 %) to avoid nuisance tripping. Its breaking capacity reaches 42 kA Icu at 12–60 V AC and 15 kA Icu at 220–240 V AC per EN/IEC 60947-2, with an Icn of 10 kA at 230 V AC per EN/IEC 60898-1 — sufficient for most commercial and light industrial panelboards where fault levels stay under 10 kA at the service entrance.

D-curve selectivity and coordination

The D-curve characteristic (12 x In magnetic trip) is the key differentiator from the more common C-curve (5–10 x In). For a 25 A circuit, the D-curve allows a short-duration inrush up to roughly 300 A before the magnetic trip operates, which is essential for motor starters, small transformers, or banks of LED drivers that draw a high starting surge. The trade-off is reduced sensitivity to lower-level short circuits, so coordination with upstream devices should be verified during panel design.

Mounts on a 35 mm DIN rail with a 2-module width (18 mm per pitch, 9 mm pitch count of 2). Terminals accept 1–25 mm² rigid or 1–16 mm² flexible conductors; strip length is 14 mm and tightening torque is 2 N·m. The IP20 finger-safe enclosure suits clean indoor panels only — not washdown or outdoor environments. A toggle control with a trip-indicator flag provides local visual status.

MPN