Skip to main content
Schneider Electric A9F08150

A9F08150 Acti9 iC60H MCB, 1P D 50 A, 15 kA Icn

MPN A9F08150
Obsolete

Schneider Electric Acti9 iC60H, 1P, D-curve, 50 A, 15 kA Icn at 230 V AC, miniature circuit breaker.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F08150 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity42 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 12...60 V DC conforming to EN/IEC 60947-2 15 kA Icu at 60...72 V DC conforming to EN/IEC 60947-2 10000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F08150 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width18 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F08150 is a 1-pole Acti9 iC60H miniature circuit breaker with a D tripping curve and a 50 A rated current. It's built for distribution boards and sub-panels where high inrush loads — motor starting, transformer energisation, or capacitive banks — demand a magnetic trip threshold of 12 x In (±20 %) to avoid nuisance tripping. The thermal-magnetic trip unit handles the overload side; the magnetic element clears short-circuits fast.

For industrial duty, the Icu per EN/IEC 60947-2 is 42 kA at 12–60 V AC, 30 kA at 100–133 V AC, and 15 kA at 220–240 V AC. On DC: 20 kA at 12–60 V DC, 15 kA at 60–72 V DC. The D curve's 12 x In magnetic trip ensures it won't drop out on motor start current, but still trips fast on a hard short.

Snaps onto a standard 35 mm DIN rail (EN 60715) and occupies 2 x 9 mm pitches (18 mm wide). Height is 91 mm, depth 78.5 mm — fits most distribution enclosures. Strip length 14 mm. IP20 rated — suitable for dry indoor panels only.

MPN
A9F08150