Schneider Electric A9F08250 Acti9 iC60H MCB, D Curve, 50 A,

MPN A9F08250
Obsolete

Schneider Electric Acti9 iC60H, A9F08250, D-curve miniature circuit breaker, 50 A rated current, 2 poles, 42 kA breaking capacity at 12-133 V AC, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F08250 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F08250 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width36 mm
Height91 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F08250 is a 50 A, 2-pole miniature circuit breaker from the Acti9 iC60H series, built for distribution panels where high inrush loads — motor starters, transformers, discharge lighting — demand a D tripping curve. The D curve means magnetic tripping occurs at 12 x In ±20 % (600 A instantaneous), so it passes the starting surge of a motor or a capacitor bank without nuisance tripping, then clears a hard short fast. Dual-rated to both EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (domestic/similar), this part carries a 42 kA Icu at 12-133 V AC and 15 kA Icu at 380-415 V AC — the 60947-2 rating is the one that governs its use in an industrial panel where fault current can hit those levels.

The 36 mm width (4 x 9 mm pitches) is the standard 2-module footprint for a 2-pole MCB — no surprise for the panel builder laying out a distribution board. Depth is 78.5 mm, height 91 mm. Terminals accept 1-35 mm² rigid or 1-25 mm² flexible, double terminal top and bottom, with a tightening torque of 3.5 N.m. Wire stripping length is 14 mm.

What compliance documentation covers this part

The manufacturer provides a declaration of conformity covering these standards; RoHS and REACH compliance is standard for Schneider's Acti9 range, though the specific statement is not in this spec excerpt. For a PO trace or nameplate check, the device short name is iC60H, the range is Acti9.