ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage12...133 V AC 50/60 Hz 220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz 440 V AC 50/60 Hz <= 180 V DC
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C

All specifications

A9F44303 additional specifications
ParameterValue
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width54 mm
Height85 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
Operating temperature-35...70 °C

Product details

Rated current and breaking capacity — what they mean for the BOM line

The A9F44303 is a Schneider Electric Acti9 iC60N miniature circuit breaker rated at 3 A with a C-curve magnetic trip characteristic (8 x In ±20 %).

Dual standard certification — the compliance gate

This breaker is certified to both EN/IEC 60898-1 and EN/IEC 60947-2. That dual certification is the compliance gate for panel builders: 60898-1 covers the domestic / commercial MCB application, while 60947-2 covers the industrial circuit-breaker role with higher interrupting ratings (50 kA Icu) and a pollution degree 3 rating, meaning it's verified for conductive-dust environments typical of control panels. The utilisation category is Category A per 60947-2, which means it is not intended for current making and breaking under fault — that is the upstream moulded-case or air breaker's job.

Panel integration — DIN rail and terminal constraints

It occupies 6 x 9 mm pitches (54 mm width) on the rail, which is the standard 3-pole MCB footprint — no surprise for a panel layout. The wire stripping length is 14 mm. IP20 finger protection is provided on the front face, so it is safe for open-panel installation but not for washdown zones. The toggle provides local on/off and trip indication; the unit can be padlocked in the off position for lockout/tagout.