A9F57116 Acti9 IKQ MCB, 16 A, 1P, C-curve, 10 kA

MPN A9F57116
Obsolete

Schneider Electric Acti9 IKQ MCB, 1P, 16 A, C-curve, 10 kA Icn at 240 V AC, thermal-magnetic, 18 mm wide.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F57116 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage240 V AC 50/60 Hz
Insulation voltage ui440 V AC 50/60 Hz conforming to EN/IEC 60898-1
Breaking capacity10000 A Icn at 240 V AC 50/60 Hz conforming to EN 60898-1
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C

All specifications

A9F57116 additional specifications
ParameterValue
Pollution degree2 conforming to EN/IEC 60898-1
ColorWhite
Depth78.5 mm
Width18 mm
Height85 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
Operating temperature-25...60 °C

Product details

The A9F57116 is a 1-pole Acti9 IKQ miniature circuit breaker rated 16 A with a C-curve (magnetic trip 5...10 x In), designed for AC networks at 240 V AC, 50/60 Hz. Its 10 kA Icn breaking capacity at 240 V (EN 60898-1) means it can safely interrupt a fault current up to 10,000 A without welding contacts or cascading upstream — sized for residential and light commercial final circuits where the prospective short-circuit current is known. The thermal-magnetic trip unit handles the long-time overload (thermal bimetal) and short-circuit (solenoid) in one package; no earth-leakage protection inside, so if you need GFCI, add a separate RCCB or RCBO downstream.

The 18 mm width (1 module pitch) and plug-on mounting to a standard DIN rail mean it snaps into any distribution board or sub-panel without extra hardware. Depth of 78.5 mm and height of 85 mm leave clearance for front-cover trim and cable bending radius. The bottom terminal accepts 1…25 mm² rigid or 1…16 mm² flexible wire; strip 14 mm and torque to 2 N·m. The toggle control and trip indicator give local status at a glance — no need to meter the load side to see if it tripped.

MPN