Skip to main content
Schneider Electric A9F68320

Schneider Electric A9F68320 Acti9 iT60 MCB, 20 A C-Curve 3P

MPN A9F68320
Active

Schneider Electric Acti9 iT60, A9F68320, miniature circuit breaker, 20 A, C-curve, 3-pole, 54 mm, DIN rail.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F68320 specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity36 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Width54 mm
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The Schneider Electric A9F68320 is an Acti9 iT60 miniature circuit breaker (MCB) rated at 20 A with a C-curve trip characteristic, 3-pole configuration, and a 54 mm width for DIN-rail mounting in distribution panels.

This MCB carries dual certification to EN/IEC 60898-1 and EN/IEC 60947-2, so it qualifies for both household-style distribution (Icn) and industrial circuit protection (Icu). The breaking capacity varies by voltage: 36 kA at 12–133 V AC, 20 kA at 220–240 V AC, 10 kA at 380–415 V AC, and 6 kA at 440 V AC per IEC 60947-2; at 400 V AC it also meets 6 kA Icn per IEC 60898-1. The limitation class is 3 per IEC 60898-1, meaning it limits let-through energy enough to protect downstream equipment in most fault scenarios — useful when coordinating with downstream sub-circuits.

Installation notes

Mounts on DIN rail, occupies 6 x 9 mm pitches (54 mm total). Terminals accept 1–25 mm² rigid or 1–16 mm² flexible copper; strip length 14 mm, tighten to 2 N·m. The removable comb busbar is pre-installed for daisy-chaining phases across multiple MCBs in the same panel row. Ambient operating range is -35 to 70 °C; storage from -40 to 85 °C at up to 95% RH.

MPN