Skip to main content
Schneider Electric A9F88420

Schneider Electric A9F88420 Acti9 iC60H MCB, 20 A B-Curve 4P

MPN A9F88420
Active

Schneider Electric Acti9 iC60H, miniature circuit breaker, 4P, 20 A, B-curve, 42 kA breaking capacity at 12-133 V AC, DIN rail mount, thermal-magnetic trip.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9F88420 key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity42 kA Icu at 12...133 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Utilization categoryCategory A conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-35 °C

All specifications

A9F88420 additional specifications
ParameterValue
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite
Depth78.5 mm
Width72 mm
Height85 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-35...70 °C

Product details

The A9F88420 is a Schneider Electric Acti9 iC60H miniature circuit breaker rated 20 A with a B-curve (magnetic tripping at 4 x In ±20 %, so 80 A instantaneous), 4 poles, and thermal-magnetic trip. It carries a breaking capacity of 42 kA Icu at 12–133 V AC 50/60 Hz per EN/IEC 60947-2, stepping down to 30 kA at 220–240 V AC, 15 kA at 380–415 V AC, and 10 kA at 440 V AC. For the EN/IEC 60898-1 rating, it delivers 15 kA Icn at 400 V AC. The 4 protected poles mean it switches and protects all four conductors in a three-phase-plus-neutral distribution circuit — typical for a sub-distribution board or a machine infeed where you need full isolation on all poles. The B-curve is the key selection parameter here: it trips magnetically between 3 and 5 times rated current, so the 20 A unit clears short-circuits at roughly 60–100 A. The thermal-magnetic trip unit covers overloads (thermal bimetal) and short-circuits (magnetic solenoid) in one package, with a separate earth-leakage block available if needed. Electrical durability is 10,000 cycles, mechanical 20,000 — figures that match the expected service life in a distribution board that sees occasional switching.

Dual-certified to EN/IEC 60947-2 (industrial) and EN/IEC 60898-1 (household / similar), so it qualifies for both industrial panel builds and commercial distribution boards.

MPN
A9F88420