Skip to main content
Schneider Electric A9K23132

Schneider Electric A9K23132 Acti9 iK60N MCB, 1P B-Curve 32 A

MPN A9K23132
Active

Schneider Electric Acti9 iK60N, miniature circuit-breaker, 1P, B-curve, 32 A, 6 kA Icn at 230 V AC, thermal-magnetic, clip-on DIN rail.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9K23132 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui440 V AC 50/60 Hz conforming to EN/IEC 60898-1
Breaking capacity6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree2 conforming to EN/IEC 60898-1

All specifications

A9K23132 additional specifications
ParameterValue
ColorWhite
Depth78.5 mm
Width18 mm
Height85 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The Schneider Electric A9K23132 is a 1-pole Acti9 iK60N miniature circuit breaker rated 32 A at 30 °C with a B-curve (magnetic trip 3...5 x In) and 6000 A Icn breaking capacity at 230 V AC, 50/60 Hz, conforming to EN/IEC 60898-1. It clips onto a DIN rail and occupies 2 x 9 mm pitches (18 mm wide), making it a standard-fit module for distribution boards in residential and light commercial panels.

The 32 A rating at 30 °C is the continuous current the breaker carries without tripping in a 30 °C ambient — above that, thermal derating applies per the IEC curve. The B-curve trips magnetically between 3 and 5 times In (96–160 A), which suits resistive and lighting loads with low inrush; it is not intended for motor or transformer starting where C or D curves are typical. The 6000 A Icn breaking capacity at 230 V AC means the breaker can safely interrupt a fault current up to 6 kA without welding or failing, which covers most domestic and small commercial service entrances where the prospective short-circuit current stays below that level. The IP20 enclosure rating means it is touch-safe but not protected against water ingress; it belongs behind a panel door or enclosure cover.

MPN