Schneider Electric A9K24603

A9K24603 Acti9 iK60N MCB, 1P+N, C-curve, 3 A, 6 kA

MPN A9K24603
Obsolete

Schneider Electric Acti9 iK60N, A9K24603, miniature circuit-breaker, 1P+N, 3 A rated current, C-curve, 6000 A Icn breaking capacity, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9K24603 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui440 V AC 50/60 Hz conforming to EN/IEC 60898-1
Breaking capacity6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree2 conforming to EN/IEC 60898-1

All specifications

A9K24603 additional specifications
ParameterValue
ColorWhite
Depth78.5 mm
Width36 mm
Height85 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The Schneider Electric A9K24603 is a 1P+N miniature circuit-breaker from the Acti9 iK60N series, rated 3 A at 30 °C with a C-curve trip characteristic (magnetic tripping between 5 and 10 times In). It breaks 6000 A Icn at 230 V AC, 50/60 Hz, per EN/IEC 60898-1, which covers the standard domestic and light commercial fault-clearing requirement.

In a 40 °C panel, expect the effective rating to drop; the thermal element responds to ambient heat. For installations where the available fault current exceeds 6 kA, you need a higher-rated upstream breaker or a current-limiting device. The C-curve (5–10 x In) means instantaneous trip occurs between 15 A and 30 A — suitable for circuits with moderate inrush, not for transformer or motor-start loads that would need a D-curve.

The 1P+N form factor takes 4 module pitches at 9 mm each, so 36 mm of rail width. Neutral is on the left, which matters when laying out busbar or comb-bridge runs in a distribution board. Tunnel terminals accept 1 to 25 mm² rigid or 1 to 16 mm² flexible copper; strip 14 mm and torque to 2 N.m. IP20 finger-safe front, but the terminals are live when the breaker is on — standard for a distribution board interior.

MPN
A9K24603