Schneider Electric A9K24720

A9K24720 Acti9 iK60N MCB, 3P+N, 20 A, C-curve, 6 kA

MPN A9K24720
Active

Schneider Electric Acti9 iK60N miniature circuit breaker, A9K24720, 3P+N, 20 A rated current, C-curve, 6 kA breaking capacity at 400 V AC, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9K24720 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui440 V AC 50/60 Hz conforming to EN/IEC 60898-1
Breaking capacity6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree2 conforming to EN/IEC 60898-1

All specifications

A9K24720 additional specifications
ParameterValue
ColorWhite
Depth78.5 mm
Width72 mm
Height85 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The Schneider Electric A9K24720 is a 3P+N miniature circuit breaker from the Acti9 iK60N series, rated 20 A at 30 °C with a C-curve trip characteristic. It breaks 6000 A at 400 V AC (Icn per EN/IEC 60898-1), which covers most residential and light commercial distribution panels — the 6 kA rating is the standard for final subcircuits in a TN or TT system where the prospective fault current at the board is under that level.

The 3P+N form factor takes 8 x 9 mm pitches of rail space — 72 mm wide. Neutral is on the left, which matters when laying out a distribution board with busbar links that expect that order. Tunnel terminals accept 1 to 25 mm² rigid or 1 to 16 mm² flexible; tighten to 2 N·m. Strip 14 mm of insulation.

Thermal-magnetic trip unit. The magnetic trip threshold is 5 to 10 times the rated current (100 to 200 A), which is the standard C-curve window — fast enough for moderate inrush from small motors or transformers, but selective enough to ride out the brief startup of a lighting bank or a few contactor coils. Rated insulation voltage is 440 V AC.