Skip to main content
Schneider Electric A9KF21216BQ

Schneider A9KF21216BQ Acti9 K60 MCB, B-Curve 16A 2P 10kA

MPN A9KF21216BQ
Active

Schneider Electric Acti9 K60 series, A9KF21216BQ, miniature circuit breaker, 2-pole, B-curve, 16 A rated current, 10 kA breaking capacity at 415 V AC, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9KF21216BQ key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz
Breaking capacity10000 A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1
IP ratingIP20
Temp storage max85 °C
Temp storage min-25 °C
Temp operating max55 °C
Temp operating min-5 °C
Storage temperature-25...85 °C
Pollution degree2

All specifications

A9KF21216BQ additional specifications
ParameterValue
ColorWhite
Depth70 mm
Width36 mm
Height81 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-5...55 °C

Product details

What this MCB does on the panel

The Schneider Electric A9KF21216BQ is a 2-pole miniature circuit breaker from the Acti9 K60 family, rated 16 A with a B-curve trip characteristic (magnetic tripping between 3 and 5 times In). It protects final circuits against overload and short-circuit in AC distribution boards, with a breaking capacity of 10 kA Icn at 415 V AC 50/60 Hz, certified to EN/IEC 60898-1. The 36 mm width (4 x 9 mm pitches) snaps onto a DIN rail, and the tunnel terminals accept up to 25 mm² rigid or 16 mm² flexible cable — sized for the incoming feed on a lighting or socket-outlet subcircuit.

B-curve selectivity and coordination

The B-curve (3–5 x In) means the magnetic trip initiates at 48–80 A instantaneous. That is deliberately higher than a C-curve's 5–10 x In, so this breaker coordinates better with upstream devices on a residential or light-commercial panel where downstream cable runs are short and inrush from incandescent or resistive loads is low.

Fixed DIN-rail mount, 36 mm wide (4 module pitches). The toggle control gives clear visual indication of the contact position.

MPN
A9KF21216BQ