Schneider Electric A9KF71210BQ

Schneider Electric A9KF71210BQ Acti9 K60 MCB, 10 A, C Curve,

MPN A9KF71210BQ
Active

Schneider Electric Acti9 K60, miniature circuit-breaker, A9KF71210BQ, 10 A, C curve, 2P, 10 kA Icn at 415 V AC, DIN-rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9KF71210BQ key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz
Breaking capacity10000 A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1
IP ratingIP20
Temp storage max85 °C
Temp storage min-25 °C
Temp operating max55 °C
Temp operating min-5 °C
Storage temperature-25...85 °C
Pollution degree2

All specifications

A9KF71210BQ additional specifications
ParameterValue
ColorWhite
Depth70 mm
Width36 mm
Height81 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-5...55 °C

Product details

The Schneider Electric A9KF71210BQ is an Acti9 K60 miniature circuit-breaker rated 10 A with a C curve, 2 poles, and a 10 kA Icn breaking capacity at 415 V AC conforming to EN/IEC 60898-1. The C curve (magnetic trip 5–10 × In) means it handles moderate inrush — typical for general-purpose distribution, lighting, and small motor loads — without nuisance tripping. The thermal-magnetic trip unit gives you both overload protection (bimetal strip) and short-circuit protection (solenoid) in one 36 mm wide, 2-pole package that snaps onto a DIN rail. Rated altitude 0–2000 m and pollution degree 2 cover the vast majority of indoor panel installations. The IP20 finger-safe terminals are fine inside a closed enclosure; if you're mounting this in a standalone box exposed to dust or moisture, the enclosure itself needs the IP rating.

The 36 mm width occupies 4 modules of 9 mm pitch — account for that in your rail fill calculation. Terminals accept 1–25 mm² rigid or 1–16 mm² flexible copper; strip length 14 mm, tighten to 2 N·m. The toggle actuator gives clear visual indication of tripped vs on/off state. No earth-leakage protection built in — if you need that, add a separate RCD downstream.