Schneider Electric A9KF71304BQ

Schneider Electric A9KF71304BQ Acti9 K60 MCB, 4 A, 3P, C-Cur

MPN A9KF71304BQ
Active

Schneider Electric Acti9 K60, miniature circuit breaker, 4 A, 3P, C-curve, 10 kA Icn at 415 V AC, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9KF71304BQ key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz
Breaking capacity10000 A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1
IP ratingIP20
Temp storage max85 °C
Temp storage min-25 °C
Temp operating max55 °C
Temp operating min-5 °C
Storage temperature-25...85 °C
Pollution degree2

All specifications

A9KF71304BQ additional specifications
ParameterValue
ColorWhite
Depth70 mm
Width54 mm
Height81 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-5...55 °C

Product details

The Schneider Electric A9KF71304BQ is a 4 A, 3-pole miniature circuit breaker from the Acti9 K60 range, built to EN/IEC 60898-1. It's a thermal-magnetic MCB with a C-curve (5–10 x In magnetic trip), rated to break 10 kA at 415 V AC. This is the part you spec for a 4 A lighting or general-purpose distribution circuit on a 3-phase panel — not a motor-protective device, but a standard branch-circuit overcurrent guard. The C-curve means it holds through inrush up to 5–10 times rated current before the magnetic trip fires, so it's a fit for mixed resistive and light inductive loads (contactors, small transformers, control transformers).

Rated for isolation per EN/IEC 60898-1, so it doubles as a disconnecting means for downstream work. That's a practical check for panel builders: you don't need a separate isolator ahead of this breaker if the circuit design allows.

Snaps onto a standard DIN rail (35 mm), fixed mounting. 54 mm wide — that's 6 modules of 9 mm pitch, which is the standard 3-pole width for this class. Height 81 mm, depth 70 mm. Tightening torque 2 N.m top or bottom. Wire strip length 14 mm. Keep it inside the enclosure. Pollution degree 2 (normal, non-conductive dust only). Operating altitude up to 2000 m, 95% RH at 55 °C, tropicalisation class 2 per IEC 60068-1. All standard for a distribution-grade MCB in a climate-controlled panel room.

Rated 20,000 electrical and 20,000 mechanical cycles. That's the endurance figure for the breaker's life under load — for a distribution board seeing occasional switching, it's more than adequate. The set ships as 4 units per package.

MPN
A9KF71304BQ