Schneider Electric A9KF71350BQ

Schneider Electric A9KF71350BQ Acti9 K60 MCB, 50 A, 3P, C-Cu

MPN A9KF71350BQ
Active

Schneider Electric Acti9 K60 series, A9KF71350BQ, miniature circuit breaker, 3-pole, 50 A, C-curve, 10 kA Icn at 415 V AC, thermal-magnetic trip, DIN-rail mount, IP20.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9KF71350BQ key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Insulation voltage ui500 V AC 50/60 Hz
Breaking capacity10000 A Icn at 415 V AC 50/60 Hz conforming to EN/IEC 60898-1
IP ratingIP20
Temp storage max85 °C
Temp storage min-25 °C
Temp operating max55 °C
Temp operating min-5 °C
Storage temperature-25...85 °C
Pollution degree2

All specifications

A9KF71350BQ additional specifications
ParameterValue
ColorWhite
Depth70 mm
Width54 mm
Height81 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-5...55 °C

Product details

The A9KF71350BQ is a 3-pole miniature circuit breaker from the Schneider Electric Acti9 K60 range, rated 50 A with a C-curve trip characteristic. The thermal-magnetic trip unit combines a bimetal element for overload protection and a solenoid for short-circuit response. The 3-pole configuration protects all three phases of a three-phase AC circuit, so it fits a 3P distribution board or a motor feeder where neutral protection is handled separately.

The 54 mm width (6 x 9 mm pitches) occupies three modular spaces on the rail — standard for a 3P MCB in European-style distribution boards. The 81 mm height and 70 mm depth fit within the envelope of a typical Acti9 enclosure, leaving clearance for wiring ducts and busbar connections. Tunnel-type terminals accept rigid conductors up to 35 mm² and flexible conductors up to 25 mm², both upstream and downstream. The 3.5 N.m tightening torque and 14 mm wire strip length are standard for this class — no special tooling required.