Schneider Electric A9L16690

A9L16690 Schneider Acti9 C neutral PV Cartridge, 65 kA

MPN A9L16690
Obsolete

Schneider Electric Acti9 C neutral PV cartridge A9L16690, Type 2 GDT surge arrester, 600 V DC, 65 kA max discharge, 20 kA nominal, < 25 ns response.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9L16690 specifications
ParameterValue
Main product or component typeCartridge
Voltage600 V DC
IP ratingIP20
Response time< 25 ns
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
ColorWhite (RAL 9003)
Depth60 mm
Width18 mm
Height50 mm
MaterialPBT (polybutylene terephthalate)
Operating temperature-25...60 °C

Product details

The Schneider Electric A9L16690 is a C neutral PV cartridge from the Acti9 range, designed as a replaceable surge protection element for the iPRD-DC SPD base module. It uses gas discharge tube (GDT) technology and is classified as a Type 2 surge arrester per EN 61643-11 and IEC 61643-1, meaning it handles induced surge currents from switching or indirect lightning strikes on electrical distribution networks.

Rated operational voltage is 600 V DC, so it's sized for photovoltaic DC strings or DC distribution busbars at that level. Maximum continuous operating voltage (Uc) is 260 V — this is the steady-state AC voltage the cartridge can sit across without degrading; the 600 V DC rating is the application voltage for the DC side of the iPRD-DC system. Maximum discharge current (Imax) is 65 kA, with a nominal discharge current (In) of 20 kA. The 65 kA figure is the single-shot survival limit; the 20 kA nominal is the level it handles repeatedly per the Type 2 test sequence. Voltage protection level (Up) is below 1.4 kV, which is the let-through voltage the protected equipment sees during a surge event. Response time under 25 ns means it clamps fast enough for most sensitive electronics on the DC side. The cartridge plugs into the iPRD-DC SPD module (mounting support: Into SPD module) and occupies 2 pitches of 9 mm on the DIN rail — 18 mm total width. Local flag signalling (white/red) gives a visual indication of end-of-life without needing to pull the cartridge. Front-face protection is IP20, so it's touch-safe inside an enclosure but not rated for wet or dusty environments.

Physical and environmental specs for panel integration

Dimensions: 18 mm wide, 50 mm high, 60 mm deep. Housing is white (RAL 9003) PBT (polybutylene terephthalate). These limits cover most indoor panel environments, including unheated electrical rooms.