Schneider Electric A9L20100

A9L20100 Acti9 iPRD20 Type 2 Surge Arrester, 1P 350V

MPN A9L20100
Active

Schneider Electric Acti9 iPRD20, Type 2 surge arrester, 1P, 350 V Uc, 20 kA Imax, 5 kA In, MOV, clip-on DIN rail.

$52.13 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9L20100 specifications
ParameterValue
Voltage230 V AC (+/- 10 %) at 50/60 Hz
Temp storage max85 °C
Temp storage min-40 °C
Storage temperature-40...85 °C
ColorWhite (RAL 9003)
Depth69 mm
Width18 mm
Height85 mm
ApplicationDistribution
Operating temperature-25...60 °C

Product details

The A9L20100 is a Schneider Electric Acti9 iPRD20 Type 2 surge arrester — a 1-pole MOV-based protector rated for 350 V maximum continuous operating voltage (Uc) on L/PE and N/PE paths. It is designed for electrical distribution network protection in IT and TN-C earthing systems at 230 V AC (+/- 10%) 50/60 Hz. The Type 2 classification means it handles induced surge currents from switching or indirect lightning strikes — not direct hits — and is typically installed at the sub-distribution board level.

The nominal discharge current (In) is 5 kA per mode (L/PE and N/PE), and the maximum discharge current (Imax) reaches 20 kA common mode on L/PE. That 20 kA figure is the one-shot survival limit — the arrester will clamp one big surge at that level, but repetitive events at Imax degrade the MOV. For daily duty, the 5 kA In rating is the design target. The voltage protection level (Up) is under 1.1 kV for Type 2 L/PE. This is the let-through voltage the equipment sees — lower is better. At 1.1 kV it is within expectations for a 350 V Uc MOV block, and it coordinates with downstream equipment rated for impulse voltages of 2.5 kV or higher per IEC 60664-1. Temporary overvoltage (TOV) withstand is specified at 337 V L/N for 5 seconds before safe failure, and 1200 V N/PE for 200 ms in safe failure mode. This means the arrester can ride through short-duration swells without catastrophic failure — important for industrial grids with generator transfers or capacitor bank switching.

Clip-on DIN rail mounting (per EN 60715) with tunnel-type terminals accepting 2.5 to 35 mm² on both top and bottom. The tightening torque is 2.5 N.m — a standard value for this conductor range, and the terminal design supports both solid and stranded copper. The 69 mm depth fits standard shallow enclosures. The arrester requires an upstream overcurrent protective device — either a circuit breaker (IC60N, iC60H, iC60L, or NG125H/L in 20 A curve C) or a gG fuse (40 A or 80 A depending on required Icu). This is not optional: the MOV block needs the disconnector to clear a fault if the varistor fails short. The associated device list covers Icu from 10 kA up to 50 kA, so you can match the SCCR of your panel.