Schneider Electric A9N16259

Schneider Electric A9N16259 Acti9 xID RCCB, 63 A, 100 mA, 4P

MPN A9N16259
Active

Schneider Electric Acti9 xID RCCB, A9N16259, 4P, 63 A rated, 100 mA sensitivity, Type AC, 400-415 V AC, DIN rail clip-on.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N16259 specifications
ParameterValue
Control typeToggle
Voltage400...415 V AC 50 Hz
Insulation voltage ui500 V AC 50 Hz
IP ratingIP20
Terminal pitch18 mm between phases
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max40 °C
Temp operating min-5 °C
Storage temperature-40...85 °C
Pollution degree2
ColorWhite
Depth75 mm
Width72 mm
Height81 mm
Electrical life cycles4000 cycles
Mechanical life cycles4000 cycles
Operating temperature-5...40 °C

Product details

The Schneider Electric A9N16259 is a 4-pole residual current circuit breaker (RCCB) from the Acti9 xID family, rated 63 A with 100 mA earth-leakage sensitivity. Rated operational voltage is 400...415 V AC at 50 Hz, with a breaking and making capacity of 630 A conforming to EN/IEC 61008-1.

The 100 mA sensitivity is less sensitive than the 30 mA version — it's sized for circuits where nuisance tripping from cable charging currents or equipment leakage is a concern, but where the fault path still needs to be interrupted before a sustained earth fault becomes a shock hazard. Type AC is the most common RCCB type; it will trip on sinusoidal AC residual currents but not on pulsed DC or smooth DC from rectifiers or VFDs. If the downstream loads include switched-mode power supplies or variable-speed drives, a Type A or Type F RCCB would be required instead. The 4-pole construction (4P) with neutral on the left covers three-phase plus neutral circuits. Insulation voltage is rated at 500 V AC, so the part is suitable for 400 V systems with headroom. The instantaneous trip time (no intentional delay) means it clears earth faults as fast as the internal mechanism allows — important for personnel protection in circuits where coordination with downstream RCBOs isn't required. Mounting is clip-on to DIN rail, occupying 8 x 9 mm pitches (72 mm wide). The tunnel-type terminals accept 1...35 mm² rigid or 1...25 mm² flexible cable, with a tightening torque of 3.5 N.m.

The part is suitable for isolation (disconnector function) and carries a contact position indicator showing ON, OFF, or fault trip status.