Schneider Electric A9N16261

Schneider Electric A9N16261 Acti9 xID RCCB, 80 A, 30 mA, 4P

MPN A9N16261
Active

Schneider Electric Acti9 xID RCCB, 4P, 80 A, 30 mA, Type AC, 400-415 V AC, DIN rail.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N16261 specifications
ParameterValue
Control typeToggle
Voltage400...415 V AC 50 Hz
Insulation voltage ui500 V AC 50 Hz
IP ratingIP20
Terminal pitch18 mm between phases
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max40 °C
Temp operating min-5 °C
Storage temperature-40...85 °C
Pollution degree2
ColorWhite
Depth75 mm
Width72 mm
Height81 mm
Electrical life cycles4000 cycles
Mechanical life cycles4000 cycles
Operating temperature-5...40 °C

Product details

The Schneider Electric A9N16261 is a 4-pole residual current circuit breaker (RCCB) from the Acti9 xID range, rated at 80 A with 30 mA earth-leakage sensitivity — the standard threshold for personal protection against direct contact in residential and commercial final circuits. That makes it suitable for general-purpose circuits feeding resistive, inductive, or lighting loads where no rectified or pulsed DC fault currents are expected.

Clip-on mounting onto a DIN rail, 18 mm phase-to-phase pitch, occupying 8 x 9 mm pitches — so 72 mm wide on the rail. Neutral on the left, tunnel terminals top and bottom accepting 1...35 mm² rigid or 1...25 mm² flexible, with a 3.5 N·m tightening torque and 14 mm strip length. The IP20 finger-safe terminals are fine for enclosed distribution boards; no washdown rating here, so keep it behind a gland plate or panel door. Padlocking provision for lockout/tagout on the toggle, with local ON/OFF/fault-trip indication on the face.

80 A rated current (In) governs the continuous load the RCCB can carry without tripping on thermal overload — sized for a 3-phase submain or a large single-phase final circuit. The 30 mA sensitivity is the IEC-recommended touch-protection threshold; it will trip on any earth fault exceeding that residual current, typically within 300 ms (instantaneous, no intentional delay). The 4000-cycle electrical and mechanical durability is standard for a switch-disconnect device in normal duty; not a high-endurance figure for frequent switching, but adequate for protection duty where the device operates only on fault or during testing.

MPN
A9N16261