Schneider Electric A9N18391

Schneider Electric A9N18391 Acti9 C120N MCB, D Curve, 80 A,

MPN A9N18391
Active

Schneider Electric Acti9 C120N, A9N18391, miniature circuit breaker, D curve, 80 A, 4P, 10 kA Icn at 400 V AC, clip-on 35 mm DIN rail.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N18391 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage380...415 V AC 50/60 Hz 220...240 V AC 50/60 Hz 440 V AC 50/60 Hz 230...400 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity10000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at <= 500 V DC conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C

All specifications

A9N18391 additional specifications
ParameterValue
Pollution degree3 conforming to IEC 60947-2
ColorWhite
Depth73 mm
Width108 mm
Height81 mm
Electrical life cycles5000 cycles conforming to IEC 60947-2
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The A9N18391 is a Schneider Electric Acti9 C120N miniature circuit breaker rated 80 A at 30 °C with a D tripping curve (magnetic trip threshold 10–14 × In). The 80 A continuous rating at 30 °C is the thermal-magnetic trip unit's baseline; per the datasheet, ambient derating applies above that temperature, so verify the panel's internal temperature if it runs hot. Breaking capacity is listed at three voltage points: 10 kA Icn at 400 V AC per EN/IEC 60898-1, and 20 kA Icu at 220–240 V AC or 6 kA Icu at 440 V AC per EN/IEC 60947-2. The 60947-2 Icu ratings give you the ultimate short-circuit capacity for industrial panel designs where the breaker is used as a disconnect under fault conditions. The 4-pole configuration (4P) switches all four poles simultaneously, with the neutral pole protected. This is the correct choice for three-phase four-wire systems (TN or TT earthing) where you need coordinated isolation and overcurrent protection on all phase conductors plus the neutral. The toggle mechanism provides local ON/OFF indication and a contact position indicator confirms the state of the moving contacts per IEC 60947-2.

The 108 mm width occupies 12 × 9 mm pitches on the rail — plan for that footprint when laying out the distribution board. Tunnel-type terminals accept 1–50 mm² rigid or 1.5–35 mm² flexible conductors; strip length is 15 mm, tightening torque 3.5 N·m. Overvoltage category IV (rated for installations at the origin of the electrical service, before the main distribution panel) confirms it can handle the higher transient overvoltages seen at the service entrance.

Dual certification to EN/IEC 60898-1 (the residential/light-commercial MCB standard) and EN/IEC 60947-2 (the industrial circuit-breaker standard) means this breaker qualifies for both domestic distribution boards and industrial panel designs. The 60947-2 certification also includes the suitability-for-isolation marking — the breaker can serve as a visible-break disconnect in the open position, per the contact position indicator.

MPN
A9N18391