Schneider Electric A9N18522

Schneider Electric A9N18522 Acti9 C120 MCB, D Curve, 63 A, 4

MPN A9N18522
Obsolete

Schneider Electric Acti9 C120 miniature circuit breaker, A9N18522, D curve, 63 A rated, 4 poles, 15 kA Icn at 400 V AC, clip-on 35 mm DIN rail.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N18522 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage380...415 V AC 50/60 Hz 220...240 V AC 50/60 Hz 440 V AC 50/60 Hz 230...400 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity15000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 10 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 30 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at <= 500 V DC conforming to EN/IEC 60947-2
IP ratingIP20
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-30 °C
Storage temperature-40...70 °C

All specifications

A9N18522 additional specifications
ParameterValue
Pollution degree3 conforming to IEC 60947-2
ColorWhite
Depth73 mm
Width108 mm
Height81 mm
Electrical life cycles10000 cycles conforming to IEC 60947-2
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-30...60 °C

Product details

The Schneider Electric A9N18522 is a 4-pole Acti9 C120 miniature circuit breaker rated 63 A at 30 °C with a D tripping curve (magnetic trip 10–14 x In). The 15 kA Icn at 400 V AC (per EN/IEC 60898-1) covers most commercial and light industrial service-entrance faults; the 10 kA Icu at 440 V AC (per EN/IEC 60947-2) handles the higher prospective fault current you might see on a transformer secondary. Dual-rated to both standards means you can spec it for either residential or industrial duty without juggling two part numbers.

D curve means the magnetic trip holds to 10–14 times rated current — it's built for transformer inrush, motor starting, or any load with a high initial surge that would nuisance-trip a C-curve breaker. At 63 A on a 400 V three-phase system, that's roughly 35 kW of connected load, so it fits a lighting sub-main, a small HVAC panel, or a machine-tool disconnect. The 15 kA Icn at 400 V AC is the rated short-circuit capacity under the domestic-standard test sequence (EN/IEC 60898-1); the 30 kA Icu at 220–240 V AC (per EN/IEC 60947-2) tells you it can interrupt a much higher fault on a 240 V single-phase leg without welding its contacts.

It's a standard catalog item in the Acti9 line, so it's routinely sourced through independent distribution.

The breaker occupies 12 x 9 mm pitches on the DIN rail — 108 mm wide total. Tunnel terminals accept 1–50 mm² rigid or 1.5–35 mm² flexible; strip 15 mm, torque to 3.5 N·m. Neutral is on the left (fixed position). IP20 finger-safe terminals, so no live metal exposed after wiring. The toggle gives clear ON/OFF indication; a separate earth-leakage block can be added downstream if you need RCD protection.