Schneider Electric A9N18577 Vigi C120 Earth Leakage Add-on B

MPN A9N18577
Active

Schneider Electric Vigi C120, earth leakage add-on block, 3P, 125 A, 500 mA, Type A, IP20, clip-on 35 mm DIN rail.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N18577 specifications
ParameterValue
Main product or component typeAdd-on residual current device
Voltage230...415 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz conforming to IEC 60947-1
IP ratingIP20
Temp storage max60 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...60 °C
Pollution degree3 conforming to IEC 60947-2
ColorWhite
Depth73 mm
Width171 mm
Height95 mm
Mechanical life cycles20000 cycles
Operating temperature-25...60 °C

Product details

Rated at 125 A continuous and 500 mA earth-leakage sensitivity, Type A (pulsating DC and sinusoidal AC fault detection), it covers the high-current distribution end of a panel — incomer or large subfeed — on a 230...415 V AC 50/60 Hz network. The 3-pole block mounts via clip-on to a 35 mm symmetrical DIN rail, with tunnel terminals accepting up to 50 mm² rigid or 35 mm² flexible conductors, torqued to 3.5 N·m.

The 125 A rated current (In) sets the continuous load capacity — sized for a main incomer or a large sub-distribution feeder, not a branch circuit. The 500 mA earth-leakage sensitivity is a high-threshold setting, typically used where nuisance tripping from leakage in long cable runs or motor drives must be avoided, rather than for personnel protection (which requires 30 mA). Type A detection covers sinusoidal AC faults and pulsating DC faults up to 6 mA DC superimposed — relevant for circuits with single-phase rectifiers, switched-mode power supplies, or variable-speed drives that can generate pulsating DC leakage. Voltage-independent tripping means the RCD operates without needing a separate power supply or the line voltage — it uses the fault current itself to trip, so it remains functional even if the neutral is lost upstream. Rated insulation voltage 500 V AC and impulse withstand 6 kV per IEC 60947-2, pollution degree 3 — suitable for industrial panels where the environment is not clean and transient overvoltages are expected.

Clip-on mounting to 35 mm DIN rail, 10 module pitches wide (171 mm), with a depth of 73 mm and height of 95 mm. The white housing and tunnel terminals are standard for panel-building; the 15 mm wire strip length and 3.5 N·m torque are typical for this conductor range. Compliant with EN 61009 and IEC/EN 61009-2-1 (the RCBO standard for RCD + MCB in one unit, though this is an add-on block), and IEC 60947-2 for the insulation and impulse ratings. IP20 finger-safe front; no washdown rating — indoor panel use only.