Schneider Electric A9N19828 Acti9 C120H MCB, 1P, D Curve, 12

MPN A9N19828
Active

Schneider Electric Acti9 C120H miniature circuit-breaker, A9N19828, 1 pole, D curve, 125 A rated current, 10 kA breaking capacity at 230 V AC, clip-on DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N19828 specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage400 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP20
Temp storage max80 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-30 °C
Storage temperature-40...80 °C
Pollution degree3 conforming to IEC 60947-2
Depth73 mm
Height86 mm
Electrical life cycles5000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-30...70 °C

Product details

The A9N19828 is a 1-pole Acti9 C120H miniature circuit-breaker (MCB) rated 125 A at 30 °C with a D tripping curve — magnetic trip between 10 and 14 times In. That D-curve characteristic is specified for loads with high inrush, such as motor starters, transformers, or discharge lighting, where the instantaneous trip threshold must ride through the starting surge without nuisance opening. The breaking capacity is 10 kA Icn at 230 V AC per IEC 60898-1 and 10 kA Icu at 230 V AC per IEC 60947-2. Dual-rated to both standards, it qualifies for distribution boards under the household standard and for industrial panel applications under the higher-fault IEC 60947-2 regime. The 73 mm depth and 86 mm height fit the standard Acti9 modular envelope, occupying 3 x 9 mm pitches on the DIN rail.

Deployment context

Clip-on mounting to a DIN rail and tunnel terminals accepting 1 to 50 mm² rigid or 1.5 to 35 mm² flexible conductors make this MCB a straightforward panel fit. Thermal-magnetic trip technology provides overload protection via the bimetal element and short-circuit protection via the solenoid — no separate earth-leakage module is integrated, though a separate Vigi block can be added downstream.

MPN
A9N19828