Schneider Electric A9N19862

A9N19862 Acti9 C120L MCB 3P 125A D Curve 15kA

MPN A9N19862
Obsolete

Schneider Electric Acti9 C120L miniature circuit breaker, 3P, 125A, D curve, 15 kA Icn at 400 V AC, DIN rail clip-on.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N19862 specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage400 V
Insulation voltage ui500 V AC 50/60 Hz
Breaking capacity15 kA Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 15 kA Icn at 400 V AC 50/60 Hz conforming to GB/T 10963.1 15 kA Icu at 400 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 400 V AC 50/60 Hz conforming to GB/T 14048.2
Temp storage max80 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-30 °C
Storage temperature-40...80 °C
Depth73 mm
Height81 mm
Electrical life cycles5000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-30...70 °C

Product details

The Schneider Electric A9N19862 is an Acti9 C120L miniature circuit breaker — 3-pole, 125 A rated current at 30 °C, D-curve thermal-magnetic trip, with a 15 kA breaking capacity at 400 V AC.

This part is officially obsolete per the manufacturer. If you're designing a new panel, the Acti9 range still carries active 3P 125 A D-curve MCBs; check the latest catalog for the current order code that matches your duty.

The same 15 kA Icu under IEC 60947-2 means it also meets the industrial standard for isolation and performance after fault interruption. The 125 A rating at 30 °C is the continuous current; derate for higher ambient temps per the thermal curve. The D-curve magnetic trip at 10–14× In (1,250–1,750 A instantaneous) is the key selection parameter for motor or transformer primary protection — it avoids nuisance trips on inrush while still clearing short circuits fast enough for cable protection.

Panel Integration & Compliance

Mounts on standard DIN rail via clip-on, 9 mm pitch per pole — 3 poles means 27 mm of rail width. The toggle handle gives local ON/OFF indication and a contact position indicator for isolation verification (suitable for isolation per the spec). Tunnel terminals accept 1–50 mm² rigid or 1.5–35 mm² flexible, torqued to 3.5 N·m. Compliance covers GB 10963.1, EN/IEC 60898-1, GB/T 14048.2, and EN/IEC 60947-2 — so it's accepted in both residential-distribution (60898) and industrial (60947) applications across Europe, China, and markets that follow those standards. Rated insulation voltage 500 V AC, impulse withstand 6 kV.