Schneider Electric A9N19863

A9N19863 Acti9 C120L MCB 4P 125A D Curve, 15 kA

MPN A9N19863
Active

Schneider Electric Acti9 C120L miniature circuit breaker, A9N19863, 4P, 125 A, D curve, 15 kA breaking capacity at 400 V AC, thermal-magnetic trip unit.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N19863 specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage400 V
Insulation voltage ui500 V AC 50/60 Hz
Breaking capacity15 kA Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 15 kA Icn at 400 V AC 50/60 Hz conforming to GB/T 10963.1 15 kA Icu at 400 V AC 50/60 Hz conforming to EN/IEC 60947-2 15 kA Icu at 400 V AC 50/60 Hz conforming to GB/T 14048.2
Temp storage max80 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-30 °C
Storage temperature-40...80 °C
Depth73 mm
Height81 mm
Electrical life cycles5000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-30...70 °C

Product details

The Schneider Electric A9N19863 is a 4-pole Acti9 C120L miniature circuit breaker rated 125 A at 30 °C with a D curve. That D-curve magnetic trip — 10 to 14 × In per GB/T 10963.1, or 12 × In ±20 % per GB/T 14048.2 — means it holds through motor inrush and high-starting-current loads without nuisance tripping.

Clip-on mounting to DIN rail, 12 module pitches wide (9 mm each — 108 mm total). The tunnel terminals accept 1 to 50 mm² rigid or 1.5 to 35 mm² flexible, with a tightening torque of 3.5 N·m. Strip 14 mm of insulation. That 4-pole footprint fits a standard panel layout; watch the fill factor if you're packing multiple high-current breakers — 125 A continuous through each pole generates heat that needs breathing room inside the enclosure.

Rated operational voltage 400 V AC, insulation voltage 500 V AC, impulse withstand 6 kV. Electrical endurance 5000 cycles, mechanical 20,000 cycles. Suitability for isolation is marked — the toggle and contact-position indicator give visible break confirmation. Thermal-magnetic trip technology covers both overload (thermal bimetal) and short-circuit (solenoid) protection in one unit.