Skip to main content
Schneider Electric A9N19892

Schneider Electric A9N19892 Acti9 DCP Vigi RCBO, 10 A, 30 mA

MPN A9N19892
Obsolete

Schneider Electric Acti9 DCP Vigi, RCBO, 2P, 10 A, B curve, 30 mA earth leakage, 10 kA breaking capacity, DIN rail mount, A9N19892.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N19892 specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Voltage220...240 V AC 50 Hz
Insulation voltage ui500 V AC 50 Hz
Breaking capacity10000 A Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1 10 kA Icu at 220...240 V AC 50 Hz conforming to EN/IEC 60947-2
Temp operating max40 °C
Temp operating min-25 °C
ColorWhite
Depth76 mm
Width36 mm
Height85 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...40 °C

Product details

The Schneider Electric A9N19892 is an Acti9 DCP Vigi residual current breaker with overcurrent protection (RCBO) — a 2-pole, 10 A unit with integrated 30 mA earth-leakage protection and a B-curve magnetic trip (3...5 x In). The 10 kA breaking capacity (Icn/Icu at 220...240 V AC, 50 Hz) is rated per EN/IEC 61009-2-1 and EN/IEC 60947-2, which means it can interrupt fault currents up to that level without welding contacts or cascading upstream — sized for residential and light commercial distribution boards where the prospective short-circuit current stays under 10 kA.

The 10 A rated current (In) is the continuous load the RCBO can carry without tripping thermally — sized for a lighting circuit, a general-purpose socket ring, or a small appliance group. The 30 mA earth-leakage sensitivity provides personal protection against direct contact — it will disconnect within 300 ms at 150 mA leakage, per the EN/IEC 61009-2-1 standard. The thermal-magnetic trip technology is the workhorse: a bimetal strip handles overloads (time-delayed), and a solenoid handles short-circuits (instantaneous). The tunnel-type terminals accept 1...35 mm² rigid or 1...25 mm² flexible cable; tighten to 2 N·m, strip 12 mm. The toggle provides ON, OFF, and fault-trip local signalling, so a technician can see at a glance whether the device has tripped on leakage or overcurrent.

MPN