Skip to main content
Schneider Electric A9N1P25DIN

Schneider Electric A9N1P25DIN Acti9 xC60 MCB, D-Curve, 25 A,

MPN A9N1P25DIN
Active

Schneider Electric Acti9 xC60 miniature circuit breaker, A9N1P25DIN, 1-pole, D-curve, 25 A rated current, 10 kA breaking capacity at 240 V AC, clip-on 35 mm DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N1P25DIN key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage220...240 V AC 50/60 Hz 12...48 V DC 60 V DC
Insulation voltage ui500 V AC 50/60 Hz conforming to IS/IEC 60947-2
Breaking capacity10 kA Icu at 220...240 V AC 50/60 Hz conforming to IS/IEC 60947-2 15 kA Icu at 12...48 V DC conforming to IS/IEC 60947-2 6 kA Icu at 60 V DC conforming to IS/IEC 60947-2
Utilization categoryCategory A conforming to IS/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C

All specifications

A9N1P25DIN additional specifications
ParameterValue
Temp operating min-30 °C
Storage temperature-40...85 °C
Pollution degree3
ColorWhite
Depth77.5 mm
Width18 mm
Height85 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-30...70 °C

Product details

25 A D-curve MCB for distribution boards

The Schneider Electric A9N1P25DIN is a 1-pole miniature circuit breaker from the Acti9 xC60 range, rated 25 A with a D-curve magnetic trip characteristic. The D-curve trips magnetically at 12 x In ±20 % — meaning instantaneous trip between 240 A and 360 A — which suits loads with high inrush current such as small motors, transformers, or solenoid banks where a B- or C-curve would nuisance-trip on startup. Breaking capacity is 10 kA Icu at 220…240 V AC 50/60 Hz per IS/IEC 60947-2, and 15 kA Icu at 12…48 V DC, so it clears fault currents up to those levels without cascading upstream. The thermal-magnetic trip unit covers overload and short-circuit protection on a single pole.

Depth is 77.5 mm, height 85 mm — fits standard distribution board enclosures with a 35 mm rail and adequate front clearance for the toggle actuator. IP20 finger-safe protection on the front face; pollution degree 3 per the standard.

MPN