Skip to main content
Schneider Electric A9N21570

Schneider Electric A9N21570 iDPN N MCB, 32 A, Curve D, 1P+N,

MPN A9N21570
Obsolete

Schneider Electric Clario iDPN N miniature circuit breaker, A9N21570, 32 A, D-curve, 1P+N, 6 kA breaking capacity, DIN rail clip-on, thermal-magnetic trip.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N21570 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage230 V AC 50/60 Hz between phase and neutral
Insulation voltage ui400 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
IP ratingIP20
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...70 °C

All specifications

A9N21570 additional specifications
ParameterValue
Pollution degree3 conforming to IEC 60947-1
ColorWhite
Depth78 mm
Width18 mm
Height81 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

What this MCB does on the rail

The A9N21570 is a 32 A, D-curve miniature circuit breaker from Schneider Electric's Clario iDPN N range, built to EN/IEC 60898-1. It protects a single pole plus neutral (1P+N) in a 18 mm wide clip-on housing that snaps onto DIN rail — no tools needed for mounting, just a screwdriver for the tunnel terminals. The D-curve magnetic trip triggers at 10 to 14 times rated current (320 to 448 A peak), so it's sized for loads with high inrush — think small motors, transformers, or capacitive supplies where a C-curve would nuisance-trip on startup. The thermal-magnetic element handles the overload side, the magnetic coil handles the short-circuit hit. Breaking capacity is 6 kA at 230 V AC, 50/60 Hz, per EN/IEC 60898-1. If your panel's SCCR exceeds 6 kA, you'll want to step up to a higher-rated breaker or add a current-limiting upstream device.

Mounting and wiring — what to expect at the panel

Clip-on mounting to DIN rail, neutral on the left. That's enough for a 32 A feed with standard building wire. IP20 rated — fine inside an enclosure, not for wet or dusty locations. The toggle gives local ON/OFF indication, and the isolation suitability (marked Yes) means it can serve as a disconnection point for the downstream circuit during maintenance, provided the supply is off.

MPN
A9N21570