Skip to main content
Schneider Electric A9N2P06BIN

Schneider Electric A9N2P06BIN Acti9 xC60 MCB, 6 A, B Curve,

MPN A9N2P06BIN
Active

Schneider Electric Acti9 xC60 miniature circuit-breaker, A9N2P06BIN, 6 A, B curve, 2P, 10 kA at 380-415 V AC, thermal-magnetic, clip-on 35 mm DIN rail, IP20, white.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9N2P06BIN key specifications
ParameterValue
Control typeToggle
Network typeDC AC
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage220...240 V AC 50/60 Hz 380...415 V AC 50/60 Hz 100...125 V DC
Insulation voltage ui500 V AC 50/60 Hz conforming to IS/IEC 60947-2
Breaking capacity10 kA Inc at 380...415 V AC 50/60 Hz conforming to IS/IEC 60947-2 6 kA Icu at 100...125 V DC conforming to IS/IEC 60947-2
Utilization categoryCategory A conforming to IS/IEC 60947-2
IP ratingIP20
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C

All specifications

A9N2P06BIN additional specifications
ParameterValue
Temp operating min-30 °C
Storage temperature-40...85 °C
Pollution degree3
ColorWhite
Depth77.5 mm
Width36 mm
Height85 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-30...70 °C

Product details

The Schneider Electric A9N2P06BIN is an Acti9 xC60 miniature circuit-breaker (MCB) rated at 6 A with a B curve, designed for distribution applications in residential and commercial panels. Its 10 kA breaking capacity at 380-415 V AC (IS/IEC 60947-2) handles typical fault levels on 400 V networks — enough to interrupt a hard short without cascading upstream. The 2-pole configuration protects both phase and neutral, and the thermal-magnetic trip unit responds to overloads (thermal) and short-circuits (magnetic) with the B curve tripping between 3 and 5 times rated current, so it's a good fit for lighting and general-purpose socket circuits where inrush is low.

The 36 mm width occupies 4 x 9 mm pitches, so it fits neatly into a 4-module slot in a consumer unit or distribution board. Depth of 77.5 mm and height of 85 mm leave clearance for wiring and enclosure depth. Tunnel terminals at the bottom accept up to 25 mm² rigid or 16 mm² flexible cable; strip length is 13 mm.

The 6 kA Icu at 100-125 V DC covers DC circuits like control power supplies or battery-backed loads. Overvoltage category IV means it's rated for installation at the origin of the installation (utility meter side), not just downstream sub-distribution. The B curve with magnetic tripping at 4 x In ±20% means it holds steady through normal inrush from resistive loads but trips fast on a short — good for lighting, socket outlets, and general-purpose circuits.

MPN
A9N2P06BIN