Schneider Electric A9P52604 Acti9 iC40 MCB, 4 A C-Curve 1P+N

MPN A9P52604
Active

Schneider Electric Acti9 iC40, miniature circuit breaker, 4 A, C-curve, 1P+N, 6 kA Icu at 230 V AC, DIN rail clip-on, thermal-magnetic.

$49.73 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9P52604 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage230 V AC 50/60 Hz
Insulation voltage ui400 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity6 kA Icu at 230 V AC 50/60 Hz conforming to EN/IEC 60947-2 4500 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2

All specifications

A9P52604 additional specifications
ParameterValue
ColorWhite
Depth74 mm
Width18 mm
Height85 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric A9P52604 is an Acti9 iC40 miniature circuit breaker rated 4 A with a C-curve trip characteristic, 1P+N configuration, and a breaking capacity of 6 kA Icu at 230 V AC per IEC 60947-2 or 4500 A Icn per IEC 60898-1. The C-curve means the magnetic trip operates at 5 to 10 times the rated current (5...10 x In per IEC 60898-1, or 8 x In +/-20% per IEC 60947-2), so it's sized for general-purpose distribution loads where moderate inrush from small motors or transformers is expected — not for high-inrush circuits like large drives or for purely resistive loads where a B-curve would be tighter. The 1P+N pole arrangement switches the phase and switches the neutral without overcurrent protection on the neutral; the neutral position is left. At 4 A, this is a low-current branch or sub-distribution MCB, not a main feeder breaker. The dual standard listing (EN/IEC 60898-1 for household and similar installations, EN/IEC 60947-2 for industrial applications) means this MCB can be specified into either a domestic consumer unit or an industrial panel, but the 6 kA Icu rating at 230 V AC is the industrial short-circuit capacity you'd use for coordination studies. The limitation class 3 (per IEC 60898-1) means it lets through less fault energy than class 1 or 2 breakers, which helps with downstream selectivity and reduces arc-flash risk at the sub-panel.

Clip-on mounting to DIN rail (35 mm symmetrical rail per EN 60715) — 2 module pitches (9 mm each, so 18 mm wide). Tunnel-type terminals accept 1...16 mm² rigid or 1...10 mm² flexible cable; strip length 14 mm, tightening torque 2 N·m. The toggle control gives local ON/OFF and trip indication via the contact position indicator.