Skip to main content
Schneider Electric A9P52632

Schneider Electric A9P52632 Acti9 iC40 MCB, 32 A, 1P+N, C-Cu

MPN A9P52632
Active

Schneider Electric Acti9 iC40 miniature circuit-breaker, 1P+N, 32 A, C-curve, 6 kA Icu, clip-on DIN rail, white.

$56.00 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9P52632 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage230 V AC 50/60 Hz
Insulation voltage ui400 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity6 kA Icu at 230 V AC 50/60 Hz conforming to EN/IEC 60947-2 4500 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2

All specifications

A9P52632 additional specifications
ParameterValue
ColorWhite
Depth74 mm
Width18 mm
Height85 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric A9P52632 is a 1P+N miniature circuit-breaker from the Acti9 iC40 range, rated 32 A with a C-curve trip characteristic. It protects final subcircuits against overload and short-circuit in AC distribution boards, and meets both EN/IEC 60898-1 and EN/IEC 60947-2 — so it's certified for residential as well as industrial isolation duty (suitability for isolation confirmed per 60947-2).

Breaking capacity is 6 kA Icu at 230 V AC per IEC 60947-2, and 4500 A Icn at 230 V AC per IEC 60898-1. The lower Icn (4500 A) is the domestic rating; both are on the same hardware. C-curve means magnetic tripping occurs between 5 and 10 times rated current (5–10 x In), with a tighter tolerance of 8 x In ±20 % per IEC 60947-2. That suits mixed loads with moderate inrush — think lighting, socket outlets, small motor circuits — where you need short-circuit protection without nuisance tripping on startup. Thermal-magnetic trip unit gives you two independent protection elements: a bimetal strip for overload (time-delayed, inverse-time) and a solenoid for short-circuit (instantaneous). No electronics to fail, no auxiliary power needed — it's the workhorse topology for distribution MCBs.

Width is 18 mm (2 x 9 mm pitches), so it occupies one modular unit. Neutral is on the left, which matters when you're laying out busbars or linking to an RCCB. Strip length 14 mm. IP20 on the body, IP40 in a modular enclosure — fine for dry indoor panels; not rated for washdown.

MPN
A9P52632