Skip to main content
Schneider Electric A9P54625

Schneider Electric A9P54625 Acti9 iC40N MCB, 1P+N, C-curve,

MPN A9P54625
Active

Schneider Electric Acti9 iC40N miniature circuit breaker, A9P54625, 1P+N, C-curve, 25 A rated current, 10 kA Icu at 230 V AC, DIN-rail clip-on.

$16.20 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9P54625 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage230 V AC 50/60 Hz
Insulation voltage ui400 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity10 kA Icu at 230 V AC 50/60 Hz conforming to EN/IEC 60947-2 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2

All specifications

A9P54625 additional specifications
ParameterValue
ColorWhite
Depth74 mm
Width18 mm
Height85 mm
Electrical life cycles10000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric A9P54625 is an Acti9 iC40N miniature circuit breaker — a 1P+N, C-curve unit rated at 25 A. The thermal-magnetic trip gives you a C-curve magnetic threshold of 5 to 10 times In (8 x In ±20% per EN/IEC 60947-2), meaning it holds through motor inrush and lighting loads but clears a hard short fast. Breaking capacity is 10 kA Icu at 230 V AC under EN/IEC 60947-2, and 6 kA Icn under EN/IEC 60898-1. For most industrial control panels fed from a 230/400 V transformer, the 10 kA Icu covers the available fault current common on a 100 kVA or smaller supply.

DIN-rail fit and panel integration

Clip-on mounting on a DIN rail, 18 mm wide (2 x 9 mm pitches). The neutral is on the left (fixed position), so when you're laying out a row of these in a distribution board, keep the phase busbar on the right side. Tunnel terminals accept 1 to 16 mm² rigid or 1 to 10 mm² flexible cable; strip length is 14 mm, torque to 2 N·m.

The A9P54625 is listed as current production. It is the standard Acti9 iC40N 25 A C-curve 1P+N MCB.

Dual-certified to EN/IEC 60898-1 (the household-breaker standard) and EN/IEC 60947-2 (the industrial-breaker standard). Pollution degree 3 per EN/IEC 60947-2, so it's rated for conductive environments typical in industrial panels. Quality marks include IMQ, OVE, RCM, and AENOR. Suitability for isolation is confirmed per EN/IEC 60947-2, meaning you can use it as a disconnecting means with the toggle in the OFF position and the contact position indicator showing the state.

MPN