Schneider Electric A9P62706

Schneider Electric A9P62706 Acti9 iC40 MCB, D Curve, 6 A, 3P

MPN A9P62706
Active

Schneider Electric Acti9 iC40 miniature circuit breaker, A9P62706, D curve, 6 A rated current, 3P+N poles, breaking capacity 4500 A Icn / 6 kA Icu, clip-on DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9P62706 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage400 V AC 50/60 Hz
Insulation voltage ui440 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity4500 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1 6 kA Icu at 400 V AC 50/60 Hz conforming to EN/IEC 60947-2
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2

All specifications

A9P62706 additional specifications
ParameterValue
ColorWhite
Depth74 mm
Width54 mm
Height85 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

Acti9 iC40 MCB, D Curve, 6 A, 3P+N

The Schneider Electric A9P62706 is an Acti9 iC40 miniature circuit breaker with a D tripping curve, rated 6 A, 3P+N poles. The D curve's magnetic trip threshold of 10–14 x In (12 x In ±20% per EN/IEC 60947-2) means it tolerates the starting surge of inductive equipment without nuisance tripping — a common requirement in industrial panel builds.

Breaking Capacity and Standards Compliance

Rated breaking capacity is 4500 A Icn at 400 V AC per EN/IEC 60898-1 for general distribution, and 6 kA Icu at 400 V AC per EN/IEC 60947-2 for industrial isolation duty. This dual rating lets the part serve both residential/commercial (60898-1) and industrial (60947-2) installations from the same SKU.

Height 85 mm, depth 74 mm. Tunnel terminals accept 1–10 mm² flexible or 1–16 mm² rigid wire; strip length 14 mm, tighten to 2 N.m. Neutral is on the left. IP20 finger-safe on the front, IP40 inside a modular enclosure. The 3P+N configuration with three protected poles and a switched neutral is standard for three-phase distribution boards where the neutral is not overload-protected but is switched with the phases.

MPN