Skip to main content
Schneider Electric A9P64310

Schneider Electric A9P64310 Acti9 iC40N MCB, 10 A, D Curve,

MPN A9P64310
Active

Schneider Electric Acti9 iC40N miniature circuit breaker, A9P64310, 3-pole, 10 A rated, D curve, 10 kA Icu at 400 V AC, thermal-magnetic trip, clip-on DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9P64310 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage400 V AC 50/60 Hz
Insulation voltage ui440 V AC 50/60 Hz conforming to EN/IEC 60947-2
Breaking capacity10 kA Icu at 400 V AC 50/60 Hz conforming to EN/IEC 60947-2 6000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-1
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2

All specifications

A9P64310 additional specifications
ParameterValue
ColorWhite
Depth74 mm
Width54 mm
Height85 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric A9P64310 is an Acti9 iC40N miniature circuit breaker (MCB) with a 10 A rated current, D tripping curve, and 3-pole configuration. The D curve means the magnetic trip operates at 10 to 14 times the rated current (10...14 x In per EN/IEC 60898-1, 12 x In ±20% per EN/IEC 60947-2). Breaking capacity is 10 kA Icu at 400 V AC per EN/IEC 60947-2, with a lower 6 kA Icn rating under EN/IEC 60898-1. The dual standard certification means it's accepted for both industrial (60947-2) and domestic (60898-1) installations — useful when the same panel feeds mixed loads.

The 3-pole body occupies 6 module pitches (9 mm each, so 54 mm total width) on a DIN rail. Depth is 74 mm, height 85 mm. That's a standard footprint — it slots into any Acti9 distribution board without crowding the adjacent devices. The tunnel-type terminals are the same top and bottom, so you can feed through or loop without re-terminating. IP20 on the body, IP40 inside a modular enclosure. Fine for most indoor panels; if you're in a dusty or humid environment, make sure the enclosure seals properly.

MPN
A9P64310