Skip to main content
Schneider Electric A9P64620

Schneider Electric A9P64620 Acti9 iC40N MCB, D Curve, 20 A,

MPN A9P64620
Active

Schneider Electric Acti9 iC40N miniature circuit breaker, A9P64620, 20 A rated current, D curve, 1P+N, 10 kA Icu at 230 V AC, clip-on DIN rail mount.

$79.70 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9P64620 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeMiniature circuit-breaker
Voltage230 V AC 50/60 Hz
Insulation voltage ui400 V AC 50/60 Hz conforming to EN/IEC 60947-2
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to EN/IEC 60947-2
ColorWhite

All specifications

A9P64620 additional specifications
ParameterValue
Depth74 mm
Width18 mm
Height85 mm
Electrical life cycles20000 cycles
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric A9P64620 is an Acti9 iC40N miniature circuit breaker — a 20 A, D-curve, 1P+N unit that clips onto a DIN rail inside a distribution board. The D curve (magnetic trip 10–14 × In per EN/IEC 60898-1, or 12 × In ±20% per EN/IEC 60947-2) is the key selection parameter: it tolerates the high inrush of motor, transformer, or welding loads without nuisance tripping, while still clearing a hard short. The 10 kA Icu at 230 V AC (EN/IEC 60947-2) tells you it can safely interrupt a fault current up to that level; the lower 6 kA Icn (EN/IEC 60898-1) is the rated short-circuit capacity for residential-type duty. For a panel builder, the 18 mm width per pole means this 1P+N unit occupies 2 modules (36 mm) of DIN rail — standard for a single-phase final subcircuit with switched neutral.

The 74 mm depth fits flush in most distribution boards; the 85 mm height and 18 mm width per pole are the standard Acti9 footprint. Terminals accept 1–16 mm² rigid or 1–10 mm² flexible copper, with a tightening torque of 2 N·m. The IP20 finger-safe front (IP40 in modular enclosure) is standard for indoor panel use. Dual-certified to EN/IEC 60898-1 (domestic) and EN/IEC 60947-2 (industrial), with pollution degree 3 and suitability for isolation. Quality labels include AENOR and OVE.

MPN
A9P64620