Schneider Electric A9R05240

Schneider Electric A9R05240 Acti9 iID RCCB, 40 A, 300 mA, 2P

MPN A9R05240
Obsolete

Schneider Electric Acti9 iID, RCCB, 2P, 40 A, 300 mA, Type A, selective, 220-240 V AC, clip-on DIN rail, IP20.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9R05240 specifications
ParameterValue
Control typeToggle
Voltage220...240 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3
ColorWhite
Depth73.5 mm
Width36 mm
Height91 mm
Electrical life cyclesAC-1: 15000 cycles
Mechanical life cycles20000 cycles
Operating temperature-25...60 °C

Product details

The Schneider Electric A9R05240 is a 2-pole residual current circuit breaker (RCCB) from the Acti9 iID series, rated at 40 A with a 300 mA earth-leakage sensitivity. The selective time delay (S-type) means it coordinates with downstream RCCBs — it holds during transient earth faults and only trips on sustained leakage, keeping the rest of the distribution board live during a downstream fault. This is critical for selectivity studies in commercial panel builds.

Rated at 40 A continuous, this RCCB handles the full load current of a typical lighting or general-purpose submain. The 300 mA sensitivity is a common choice for fire protection in commercial and industrial installations — it avoids nuisance tripping from normal leakage in long cable runs or equipment with filters, while still clearing a ground fault that could cause arcing. The voltage-independent residual current tripping technology means the device does not need an external power supply to detect leakage — it will still trip even if the line voltage drops or the neutral is lost upstream. This is a reliability advantage over electronic RCDs in harsh supply conditions.

Installation and compliance notes

Designed for clip-on mounting on a DIN rail. IP20 rated (finger-safe) for the device body; IP40 when installed in a modular enclosure. Compliant with EN/IEC 61008-1 for RCCBs. The 8/20 µs impulse withstand of 3000 A ensures it survives surge events without nuisance tripping.

MPN
A9R05240