Skip to main content
Schneider Electric A9R31463

Schneider Electric A9R31463 Acti9 iID RCCB, 63A, 30mA, Type

MPN A9R31463
Active

Schneider Electric Acti9 iID, RCCB, 4P, 63 A, 30 mA, Type A-SI (Super Immunised), 380-415 V AC, IP20/IP40, EN/IEC 61008-1.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9R31463 specifications
ParameterValue
Control typeToggle
Voltage380...415 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3
ColorWhite
Depth73.5 mm
Width72 mm
Height91 mm
Electrical life cyclesAC-1: 15000 cycles
Mechanical life cycles20000 cycles
Operating temperature-25...60 °C

Product details

The Schneider Electric A9R31463 is a 4-pole Acti9 iID residual current circuit breaker (RCCB) rated at 63 A with 30 mA earth-leakage sensitivity. It provides personnel protection against direct and indirect contact, tripping instantaneously on fault currents above the threshold. The Type A-SI (Super Immunised) classification means it handles pulsed DC fault currents and is immune to nuisance tripping from high-frequency harmonics or transient surges common on modern electronic loads — variable-speed drives, switched-mode power supplies, and UPS systems won't cause false trips.

The 6 kV rated impulse withstand voltage (Uimp) ensures it survives transient overvoltages on the supply side without internal flashover. The 30 mA sensitivity is the standard for personnel protection. The instantaneous time delay means it trips within milliseconds of a fault.

Clip-on mounting to DIN rail (35 mm symmetrical rail per EN 60715). Occupies 8 x 9 mm pitches (72 mm width) in the enclosure. Neutral position is left, which is standard for 4P RCCBs in most European distribution boards. The toggle control provides a clear mechanical contact position indicator — you can see the state without powering the panel. Terminals accept 1-35 mm² solid or 1-25 mm² flexible conductors. Wire stripping length is 14 mm.

Compliance documentation: the RCCB is certified to EN/IEC 61008-1 (the harmonized European standard for residual current operated circuit-breakers without integral overcurrent protection). The electromagnetic compatibility is verified with an 8/20 µs impulse withstand of 3000 A per that standard. No UL or CSA listing is stated on this variant — confirm jurisdiction-specific approvals for North American installations.

MPN
A9R31463