Schneider Electric A9R74240

Schneider Electric A9R74240 Acti9 iID RCCB, 40 A, 300 mA, Ty

MPN A9R74240
Active

Schneider Electric Acti9 iID, residual current circuit breaker (RCCB), 2P, 40 A, 300 mA, Type AC, 220-240 V AC, clip-on DIN rail mount.

$44.14 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9R74240 specifications
ParameterValue
Control typeToggle
Voltage220...240 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C
Storage temperature-40...85 °C
Pollution degree3
ColorWhite
Depth73.5 mm
Width36 mm
Height91 mm
Electrical life cyclesAC-1: 15000 cycles
Mechanical life cycles20000 cycles
Operating temperature-5...60 °C

Product details

The Schneider Electric A9R74240 is an Acti9 iID residual current circuit breaker (RCCB) — a 2-pole, 40 A, 300 mA sensitivity unit that clips onto a DIN rail. It's a Type AC device, meaning it trips on sinusoidal AC earth-leakage currents only, which covers the majority of standard building and industrial final circuits. The 300 mA sensitivity is a common choice for protection against fire risk from earth faults rather than personnel shock protection (that's the 30 mA job). It's rated for 220-240 V AC networks at 50/60 Hz.

The 40 A rated current (In) and 300 mA sensitivity are the two numbers that decide whether this RCCB fits your distribution board. At 40 A, it's sized for a submain or a heavy final circuit — think a large commercial kitchen, a workshop sub-board, or a multi-tenant meter tail. The 300 mA trip threshold is above the 30 mA required for personal protection, so this unit is deployed for equipment protection or fire-prevention earth-leakage detection on circuits where nuisance tripping from capacitive leakage (long cable runs, VFDs) would be a problem. Breaking capacity is listed as Idm 1500 A and Im 1500 A — that's the maximum fault current the RCCB can safely interrupt. In a domestic or light commercial panel with a 10 kA upstream MCB, this is adequate because the RCCB sees the let-through current, not the full prospective fault level. The rated impulse withstand voltage of 6 kV (Uimp) and insulation voltage of 500 V AC give it headroom for industrial environments with switching transients.

Clip-on mounting to a DIN rail, 36 mm wide (4 x 9 mm pitches), 91 mm tall, 73.5 mm deep. The IP20 rating means it's for use inside an enclosure, not in a wet or dusty location. The white housing is standard for the Acti9 range, and the toggle control gives a clear visual indication of contact position.