Skip to main content
Schneider Electric A9R91463

Schneider Electric A9R91463 Acti9 iID RCCB, 63 A, 30 mA, 4P

MPN A9R91463
Active

Schneider Electric Acti9 iID RCCB, 63 A, 30 mA, 4P, Type A-SI, 380-415 V AC, clip-on DIN rail.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9R91463 specifications
ParameterValue
Control typeToggle
Voltage380...415 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degree3
ColorWhite
Depth73.5 mm
Width72 mm
Height91 mm
Electrical life cyclesAC-1: 15000 cycles
Mechanical life cycles20000 cycles
Operating temperature-25...60 °C

Product details

The Schneider Electric A9R91463 is a 4-pole residual current circuit breaker (RCCB) from the Acti9 iID series, rated 63 A and 30 mA earth-leakage sensitivity. The 63 A rated current (In) sizes it for the main incoming supply or a large submain, not a final subcircuit. It is a Type A-SI (Super Immunised) device, meaning it handles sinusoidal AC residual currents plus pulsed DC (Type A) and resists nuisance tripping from transient surges or high-frequency leakage typical of VFDs and UPS systems. The voltage-independent tripping mechanism works without an external supply — the fault current itself powers the trip coil. Rated operational voltage is 380-415 V AC 50/60 Hz, which covers the standard three-phase European low-voltage network. The insulation voltage (Ui) is 500 V AC, giving headroom for the rated voltage class. Breaking and making capacity is 1500 A (Idm and Im), adequate for the fault levels typical at the outgoer position in a domestic or small commercial distribution board. The surge current withstand is 3000 A (8/20 µs impulse), conforming to EN/IEC 61008-1.

Clip-on mounting on DIN rail, 8 x 9 mm pitches wide (72 mm). Neutral on the left. The toggle control and padlocking device allow lockout/tagout during maintenance. Terminals accept 1-35 mm² rigid or 1-25 mm² flexible wire; tightening torque 3.5 N.m. Wire stripping length 14 mm. The 73.5 mm depth fits standard shallow enclosures — verify the gland plate clearance if back-mounting.

MPN