Skip to main content
Schneider Electric A9V01240

Schneider Electric A9V01240 Vigi iC60, 40A 30mA AC Type RCD

MPN A9V01240
Obsolete

Schneider Electric Acti9 Vigi iC60 add-on residual current device, A9V01240, 2P, 40 A, 30 mA sensitivity, Type AC, voltage-independent tripping.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

A9V01240 specifications
ParameterValue
Main product or component typeAdd-on residual current device
Voltage110...130 V AC 50/60 Hz conforming to EN/IEC 61009-1 110...130 V AC 50/60 Hz conforming to EN/IEC 61009-2-1
Insulation voltage ui500 V AC 50/60 Hz conforming to IEC 60947-2
Temp storage max85 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min-5 °C
Storage temperature-40...85 °C
Pollution degree3 conforming to IEC 60947-2
Depth73.5 mm
Width72 mm
Height91 mm
Operating temperature-5...60 °C

Product details

The Schneider Electric A9V01240 is an add-on residual current device (RCD) from the Acti9 Vigi iC60 range, designed to clip onto the outgoing side of an iC60 MCB. It provides earth-leakage protection for a 2-pole circuit, rated at 40 A with a 30 mA sensitivity, Type AC (sinusoidal AC residual currents only). The unit is voltage-independent — the tripping mechanism does not rely on the line voltage to detect a fault, which means it remains functional even if the neutral is lost upstream.

The 40 A rated current (In) sets the continuous load this RCD can carry — sized for a 40 A feeder or submain, not for a final subcircuit below that rating. The 30 mA sensitivity is the standard for personal protection against indirect contact in most residential and commercial installations per IEC 60364. The voltage-independent tripping technology is a differentiator: the RCD stores enough energy from the fault current itself to trip the mechanism, so a lost neutral or a voltage sag on the supply side does not disable protection. This is standard for most electromechanical RCDs but worth confirming if the specification calls for it explicitly.

Clip-on mounting to DIN rail (EN/IEC 60715). The unit occupies 4 modules of 9 mm pitch (72 mm total width). It is an add-on block that screws directly to the outgoing side of an iC60 MCB — the electrical connection is made via screws, not busbars, so the assembly forms a single combined RCBO-like unit. IP20 on the device body, IP40 when enclosed in a modular enclosure per IEC 60529.

The 8/20 µs impulse withstand rating of 250 A per IEC 61009-1 confirms the device can survive common surge currents without nuisance tripping.

MPN
A9V01240